
26 User Manual THEIA HE-t String Inverters 357115.013, Issue 1.0, 2011 March
Stringbox
If provided, the Stringbox is attached to the bottom of the inverter, and provides PV string
connection via the wiring that runs through either plug-in connectors or cable glands. A DC
disconnect switch may be provided and mounted in the stringbox.
NOTICE!
Ensure the DC switch is in the OFF position when removing the lower cover to access the
connection terminals.
Figure 4.3.5: DC disconnect switch
I = ON
0 = OFF
There are three different configurations of the stringbox:
1. Stringbox with DC fuse holders and DC switch
2. Stringbox with DC fuse holders and no DC switch
3. Stringbox with DC switch and no DC fuse holders
1. Stringbox with DC Fuse Holders and DC Switch
The Stringbox can be equipped with DC fuse holders, DC switch and plug-in connectors or
cable glands.
Figure 4.3.6: Optional DC connectors
P1, P2, P3:
Positive connectors
N1, N2, N3:
Negative connectors
Comentarios a estos manuales