Follow the next instructions to avoid arcing when reconnecting the terminals:
• Turn OFF the DC switch(es) and the AC circuit breaker(s).
DANGER:
Never work with live wires!
The PV conductors are still charged after the DC switch in the Stringbox is turned
OFF, due to power fed from the PV modules. Always turn OFF the remote DC
switch and wait until the PV modules do not feed power.
• Remove the PV connectors.
• Check with a voltmeter if the terminals are discharged.
• Disconnect the conductors from the terminal block.
• Connect the conductors to the correct terminal block.
• Test the polarity using a voltmeter before turning ON the DC switch(es) and the AC circuit
breaker(s).
Jumper Position for the System Grounding Setup
The jumper above the - NEG terminal in the customer connection area monitors the
arrangement of the DC connection according to the system grounding setup. When delivered,
the jumper is positioned for an ungrounded string configuration as a standard. Depending on
the grounding requirements from the module manufacturer the jumper must be pulled up and
positioned correctly to match the required grounding of the PV strings.
In case of discrepancy a message will appear in the display (See 7.2. Table of Events).
Table 4.3.1: Position for the jumper monitoring the grounding setup
Connection Area
From the
side
From
above
System
Ungrounded PV String
There is no connection between the
pins.
Positive grounded PV String
The jumper short-circuits pin 1 and
pin 2.
Negative grounded PV String
The jumper short-circuits pin 2 and
pin 3.