Eltek Valere Theia He-t Guía de instalación Pagina 31

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 30
Installation Guide THEIA HE-t String Inverters 357115.033, Issue 2.0, 2011 March 31
10. Message 2
Enter – Call up the keyboard
This message field is to help distinguish
and identify specific inverters in a larger
PV plant, or for any other information.
Left – Back
Right – Next
EnterConfirm
11. Owner Password
Enter – Call up the digits
Default: 0003.
Change the password to 4 optional digits
Left – Back
Right – Finish
EnterConfirm
This password is not transmitted to other
inverters on the CAN bus
NOTICE
When several inverters are connected, check that the installation is carried out on all the slave
inverters:
Look at the menu displayed and the LEDs. Installation is not carried out correctly if the
installation menu is still displayed and/or the yellow and red LEDs are lit.
Check that the connection of the CAN cables are correct, that the DC switches are on and
that the power is >7 W
DC
.
If the Start Up phase is correctly carried out, then the inverters are ready to use. They are
fully automatic during normal operation, and no manual control is necessary for feeding
power into the grid.
Vista de pagina 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36

Comentarios a estos manuales

Sin comentarios